Information that may be relevant for landlords or building management companies, as well as tenants, related to high-rise safety and outcomes of the Grenfell report is available below.
Presently enforceable under the Regulatory Reform (Fire Safety) Order 2005
- All residents should be aware of the evacuation plan and what they need to do in event of a fire (whether in their flat, the common areas or another flat)
- fire doors are extremely important to the passive fire measures in the building. It is important that they are checked regularly to ensure that they continue to carry out their function.

Residential Personal Emergency Evacuation Plans (RPEEPs)
The Fire Safety (Residential Evacuation Plans) (England) Regulations 2025 take effect from 6 April 2026.
They aim to improve the fire safety and evacuation of residents in specified residential buildings in England who would have difficulties evacuating a building by themselves in the event of a fire (relevant residents). This may be due to a physical mobility issue, some other disability such as having a sight or hearing impairment, or a cognitive condition. The regulations also mandate building emergency evacuation plans in these buildings.
What buildings do these regulations relate to?
The Regulations apply to all buildings that contain two or more sets of domestic premises, and which is either: at least 18 metres above ground level or have at least seven storeys; is more than 11 metres in height above ground level that has simultaneous evacuation strategies in place.
What will they require?
- the responsible person of a relevant premises will need to identify those residents with mobility or other impairments and create a person centred fire risk assessment with the consent of the resident to support their evacuation
- a written Emergency Evacuation Statement should be created for each relevant resident with their consent specifying what they should do in the event of a fire
- the Responsible Person will need to review the person centred fire risk assessment with the resident every 12 months or where amendments or updates are identified e.g. where the condition of the resident has changed
- with the resident’s explicit consent, the responsible person will need to share the relevant residents details with the fire service including:
> the resident’s flat number and floor number
> basic information regarding the degree of assistance that the resident may require to evacuate the building
> whether the resident has an emergency evacuation statement
This information should be shared with us via our dedicated portal for Responsible Persons. This must be reviewed every 12 months, or as and when updates or amendments are made to the evacuation plan.
These new regulations are subject to the residents consent, GDPR and Data Protection regulations. We are not allowed to share this information with others and the data is held to support response to operational incidents. A resident or their relevant representative is free to withdraw their consent for this shared information at any time.
Download a copy of our RPEEPS awareness letter if you are a responsible person/managing agent of a relevant premises and want to know more.
Click to watch an explanatory video for Responsible Persons: https://youtu.be/YknsqwUoFM4
Click to download a blank template of a Residential Personal Emergency Evacuation Plan
Click to download a blank template of a building emergency evacuation plan
We will not arbitrate any disputes between a Responsible Person and a resident as part of the RPEEPs process. If there’s a dispute, we’ll advise you to refer the disagreement to an appropriate dispute resolution process, such as your complaint’s procedure, an ombudsman service, or the relevant housing authority.
Further guidance for Responsible Persons
GOV.UK provides detailed guidance and practical tools to support you, including:
- The Responsible Person (RP) Toolkit
- RPEEP Guidance for Responsible Persons
- Residential PEEPs: Factsheet
Refer a resident with an RPEEP for a Safe and Well visit
Fire and rescue services across the Midlands have committed to offering face-to-face Safe and Well visits to residents who have a RPEEP in place.
Once you have completed a resident’s RPEEP, please consider referring them to us for a Safe and Well visit using this link. You can use the link whether or not you have an existing referral pathway with us. If you would like to set up a pathway, please contact prevention.queries@wmfs.net
From January 23 2023, new regulations will come into force under Article 24 of the Fire Safety Order, which applies in England, and govern steps and guidance that a responsible person for a premises needs to take or follow to ensure fire safety in residential premises that are:
- High-rise buildings
- buildings 11 metres or taller
- premises with more than one residential premises contained within – for example, a house converted into flats.
We’ve put together detailed guidance for responsible persons on the requirements for these different types of properties. Visit our Residential Fire Safety page for further information. The full Regulations can be found on the UK Government website.
Best Practice
Recommendations from the Grenfell Tower Inquiry phase 1 report: –
- Regular inspections of individual flat front doors
- each floor should be marked at a low level with the floor number. This action will greatly assist firefighters in the event of a fire and smoke logging of the staircase/corridors. This will improve firefighter safety and ensure that any rescues are not unduly delayed
- that all lifts including firefighting lifts should be inspected regularly, and the reports collated by the responsible person. If a lift fails during a fire incident, immense pressure is placed on those at the incident and delays in tackling the fire and rescue may occur
- fitting of Premises Information Boxes (PIB) – which will contain the provision of secure information to the fire and rescue service for use in firefighting actions
- simple floor plan layouts indicating any relevant fire resistance provisions, internal access provisions, firefighting facilities, building services and specific hazards
- relevant information including operating instructions for any equipment or for any fixed installations for firefighting or means of escape
- fire engineering strategy
- information relevant to preventing environmental damage
- relevant information and operating instructions relating to lifts provided for means of escape or firefighting
- personal Emergency Evacuation Plans (PEEP) should be arranged for vulnerable people living within the building
- the provision of up-to-date electronic plans for the local fire and rescue service
- an evacuation plan should be clearly visible within the building.
For premises-specific guides, which are issued by the government, please visit our fire risk assessment page.