Ref: FOI/24126
RE: FREEDOM OF INFORMATION ACT 2000 REQUEST
I am writing to confirm that the West Midlands Fire Service has now completed its search for the information you requested further to your Freedom of Information request.
Please find below a summary of our findings.
Request
When attending a thermal runaway in a workplace, before handing the site back over to management what testing do the fire service conduct before deeming the workplace safe?
Do you test for contaminants found on the E40 workplace exposure limits or is that something the H&s team conduct once the site is handed back to management.
Reply
Our IOR (Initial Operational Response) Have the facility to monitor gases with a five channel monitor that is capable of monitoring the following gases:
Oxygen
Hydrogen Sulphide
Hydrogen Cyanide
Carbon Monoxide
Lower explosive limit-Gases likely to be a flammable risk calibrated to Methane.
The crews would be able to check for the presence of the above gases in order to help aid the decision to repopulate a workplace/building. Not all gases would be detectable individually, but should a significant amount appear in the atmosphere, this would cause the displacement of Oxygen, displayed as a drop in percentage from the standard 20.9%
Thermal runaway would produce many different gases, dependent on the “Fuel” of the item involved in the initial conflagration. With all the available items capable of such a phenomenon, it would be remiss to claim to be able to detect all of them. This is why the detectors we use, detect the gases listed above.They are the most common found product gases of combustion. Oxygen is monitored to make aware the displacement by other products of combustion.
The ultimate decision to repopulate an area is that of the person responsible for the site. We can only advice within “The limitations of the equipment.” If special equipment or process used has a probability of causing thermal runaway, then it would suggest those responsible for managing that process would identify specific gases like to be produced within their own systematic risk assessment, and have a system in place, or have facility to obtain the relevant environmental monitoring equipment.
Request
West midlands fire service have several times attended a workplace called goodman Sayer Dr, Coventry CV5 9D. It’s run under the name of Goodman but it is a Jaguar Land Rover site. Could you provide me with dates, times and duration of attendance at this workplace between the dates of 01.01.23 – 01.05.24.
Reply
| Date | Time | Hours on Scene |
| 16/01/2023 | 10:48:56 | 8.88 |
| 14/09/2023 | 13:27:02 | 4.86 |
| 11/11/2023 | 04:30:46 | 19.26 |
| 22/02/2024 | 05:01:11 | 28.23 |
| 07/03/2024 | 07:19:57 | 3.57 |
| 03/04/2024 | 12:15:01 | 1.48 |
Request
There was a thermal runaway back in November 2023 which WMFS attended, they also attended site in January and April 2024. Could you please provide me with any incident reports made after attending the site back in april 2024.
Reply
We cannot supply Incident Reports unless you have a direct connection to the property.
If you have any queries about this Freedom of Information request, please contact us. Please remember to quote the reference number above in any future communications.
For service complaints, issues or comments regarding this request please contact The Public Relations Department, West Midlands Fire Service, 99 Vauxhall Road, Birmingham, B7 4HW