Fire Vehicles: Equipment and Quantity
Where applicable, we publish responses to requests under the Freedom of Information Act 2000. This one, Fire Vehicles: Equipment and Quantity, is detailed below.
Other FOI's
Ref: FOI25087
RE: FREEDOM OF INFORMATION ACT 2000 REQUEST
I am writing to confirm that the West Midlands Fire Service has now completed its search for the information you requested on 14/06/2025.
Please find below a summary of our findings:
Request:
Could you please prove what equipment and quantity is carried on all vehicle types within your service.
| 1 | FIPS | Some of this information is exempt under Section 21 of the Freedom of Information Act 2000 as this information is reasonably accessible to the requestor. The information can be found on the West Midlands Fire Service website at the following links: 23113 – Fire Investigation Equipment – West Midlands Fire Service 21131 – Equipment on Hydraulic Platform (HP) – West Midlands Fire Service |
| 2 | HP | |
| 3 | Occupation Health MPV | 1 x Audiogram 1 x Spirometer 1x Weighing Scales 1x Fitness assessment test 1x Mannequin 2 x Barbell weights |
| 4 | OLPD Training Vehicles | There is a selection of equipment that depends on modules or course lead for specific day |
| 5 | Response – MPV (Drone Team) | We have a selection of drones in which individual specialists handle and carry on a daily basis, according to our operational needs |
| 6 | Warehouse and Distribution – vans | 1x Penny Hydraulic Lift 1x Small Extinguisher 1x First Aid Box Cylinder Boxes Ratchet Straps |
| 7 | Workshops (3 service vans) | According to the nature of work we are called out too, we will load our vans with equipment that is necessary for that day |
| 8 | Youth Services – Vans/PRL | As standard, there is no equipment carried on these vehicles under normal circumstances. Cadet PRLs may be utilised to carry equipment for events but as standard, no equipment is carried on these at all times |
| 9 | Safeside – Van | No equipment are carried on these vehicles |
| 10 | International Search and Rescue (ISAR) | Technical Rescue deals with incidents that require additional equipment and training outside the remit of standard firefighting, this can include water rescue, rope rescue, animal rescue, response to terrorist threats and more, which would carry many kinds of equipment. |
| 11 | Road Safety –Van | Child car seat attached to a display seat Set of 10 magnetic display messages for the outside of the van showing fatal 5 messages 10 cones to assist coning areas around the van for safety 5 banners with road safety messages 3 Hi-Viz jackets to wear when required at events |
| 12 | Response Specialist Vehicles & Detection, Identification & Monitoring (DIM) | DIM equipment will be deployed by the DIMA with the initial aim of delivering a substance detection, analysis and identification capability. DIM equipment will be deployed, where appropriate, to monitor the scene as decided by the FRS IC in liaison with the Police IC and in consultation with FRS DIMA and HMA. |
| 13 | Hydrant Technicians | 1x Petrol/Diesel Container 10 Ltr 1x Chrome Hydrant Key & Bar 1x Trundle Wheel 1x Shovel 1x Watermans Hydrant Key & Bar 1x Hydrant Listening Stick 1x Hard Hat 1x Battery Powered Torch Hydrant Plates & Hydrant Plate Accessories 2x Safety Glasses 8+ False Spindles 1x Metal Detector 1x Standard Hose Branch 1x Toolbox 5x Large Traffic Cones PPE 1x Safety Shoes 1x Safety Boots (Steel Toe Capped and Steel Sole) 1x Hi-Vis Waterproof Trousers 1x Hi-Vis Tabard 1x Waterproof Hi-Vis Winter Jacket 1x Traffic Management Stand 1x ‘Keep Right’ Traffic Management Sign (Plastic, Foldable) 1x Small pop up cone |
| 14 | PRL | 6x Road Cones 1x 15m Line 1x Peli Scene lamp 6x Road Cone lights 4x Step blocks 20x Blocks & Wedges 2x Air Bags 1x Stabfast Unit 1x 10m Holmatro Hose Set 1x Casualty Shield 2x Spare BA set 1x Hose Reel & Branch 1x Fire Extinguishers Dry Powder and C02 1x Fuel Can 1x Dust Pan and Brush 4x Blue Beacons 1x Hazard Tape 1x Chimney hose 1x Foam dip tube 3x Oxygen Cylinders 1x Peli Case containing Extended duration valve 7x 25m Lengths Flaked Hose 2x Hose 45mm 4x Hose 64mm 1x A WG Mini Ejector Pump 2x Accident sign and tri-pod 2x Hose ramp 1x Hose reel rewind foot control pedal 1x Peli LED Lamp 1x Vehicle DP Fire Extinguisher 1x First Aid Kit 2x BA sets 5x Life Jacket 5x Helmets 1x Automated External Defibrillator 1x Spare Oxygen cylinder 2x Plastic Sheets 2x D Rings |
| 15 | BRV | 2x Drager PS700 BA sets with smoke hoods attached 1x Drager Merlin Entry Control Board 1x BRV Trauma pack 1x AED 1x North American Emergency Response Guidebook 1x FireFax Folder 1x Vehicle First Aid Kit 1x Crew Board 1x Hi-Viz Jerkins – Ops Commander 1x Hi-Viz Jerkins – Safety Officer 1x Hi-Viz Jerkins – Incident Commander 1x Hi-Viz Jerkins – Tactical Advisor 3x Hi-Viz Jerkins – Fire 1x 2KG Co2 Extinguisher 1x Standpipe 1x Short length 64mm delivery Hose 1x Arctic Survivor Life Jacket 2x Fire Retardant Life Jackets 1x 64mm hose 1x 30m Water Rescue throw line 1x Folding ladder 1x Electrical gloves 3x BA Torches 6x Collapsible Road Cones 6x E-Flare Road Cone Lights 1x Milwaukee Tripod Scene Light 1x Tool Roll 1x Stabfast 1x Webber Combi-tool 1x Accident Sign 3x Fire Kit Stowage 1x Getch Tool 1x Hose Reel (55m x 22mm) 2x 64mm Delivery Hose 4x Smoke detectors 1x Reel of Traffic Tape 1x Reel of Hazard Tape 1x Hose Reel Mop-Branch 1x Metal Bucket 1x Brigade area Map Book |
After careful consideration, we are unable to disclose all requested information regarding all our Fire Service appliance equipment.
This decision is based on the following exemptions:
Section 24 – National Security (Qualified Exemption)
The disclosure of the equipment and quantity of what our vehicles carry could adversely affect national security by providing individuals or groups with information that may assist in planning or carrying out acts that threaten public safety. The release of such information could undermine emergency response capabilities, putting both firefighters and the public at greater risk.
Section 24 of the Freedom of Information Act 2000 is a qualified exemption where disclosure would be likely to prejudice national security. Since this is a qualified exemption, a public interest test must be conducted to determine whether the public interest in maintaining the exemption outweighs the public interest in disclosure.
Factors in favour of disclosure:
- Transparency and Accountability:
Disclosure of information about emergency service equipment may enhance public understanding of operational readiness and allocation, promoting trust in public services.
- Public Confidence:
Providing insight into the capabilities of emergency services could reassure the public that appropriate measures are in place to respond to incidents effectively.
Factors in favour of maintaining the exemption:
- National Security Risk:
Revealing specific details about the equipment and quantities carried and used by emergency vehicles could offer individuals or groups access and knowledge of some specialist equipment that could potentially aid in the planning of acts that threaten public safety.
- Operational Integrity:
Disclosure could compromise the effectiveness of emergency response strategies, particularly in high-risk or sensitive scenarios, thereby endangering both responders and the public.
- Targeting Risk:
Knowledge of equipment distribution may allow malicious individuals to target specific vehicles or locations, undermining emergency service operations and increasing the risk to life and property.
Section 38 – Health and Safety (Qualified Exemption)
The disclosure of this information may endanger the physical or mental health and safety of individuals, including firefighters and members of the public.
As this is a qualified exemption, the public interest test has been applied. While public awareness of emergency procedures is important, we consider that releasing this information would create a significant risk to public safety, and therefore, the exemption is upheld.
A public interest test must be conducted to assess whether the public interest in maintaining the exemption outweighs the public interest in disclosure.
Factors in favour of disclosure:
- Transparency and Accountability:
Disclosure of information about emergency service equipment may enhance public understanding of operational readiness and allocation, promoting trust in public services.
- Public Reassurance:
Knowledge of the tools and resources available to emergency responders may reassure the public that appropriate measures are in place to protect them in emergencies.
Factors in favour of maintaining the exemption:
- Risk to Public and Firefighter Safety:
Disclosure of detailed knowledge of Fire Service equipment could be misused to create hazardous situations or obstruct emergency response efforts, endangering both firefighters and the public.
- Potential for Misuse:
Individuals with malicious intent could use the information to plan actions that obstruct or undermine emergency operations, increasing the risk of harm during incidents.
- Operational Vulnerability:
Revealing specific capabilities or limitations of equipment may expose operational vulnerabilities, reducing the effectiveness of emergency responses and increasing the likelihood of harm.
If you have any queries about this Freedom of Information request, please contact us. Please remember to quote the reference number above in any future communications.
For service complaints, issues or comments regarding this request, please contact:
The Public Relations Department, West Midlands Fire Service, 99 Vauxhall Road, Birmingham, B7 4HW.
Further information concerning Freedom of Information requests can be found on the Information Commissioner website at either the following link: https://ico.org.uk/ or at Wycliffe House, Water Lane, Wilmslow, SK9 5AF.